Submit a ticketCall us

Get a crash course on Network Monitoring delivered right to your inbox
This free 7-day email course provides a primer to the philosophy, theory, and fundamental concepts involved in IT monitoring. Lessons will explain not only how to perform various monitoring tasks, but why and when you should use them. Sign up now.

Home > Success Center > Server & Application Monitor (SAM) > SAM 6.4 Administrator Guide > Monitor your network with SAM > Set up and monitor Cisco Unified Computing Systems (UCS) in SAM

Set up and monitor Cisco Unified Computing Systems (UCS) in SAM

Table of contents
No headers

Updated: 3-9-2017

To gain an overview of all information provided by UCS, add the UCS master device, and the primary fiber interconnect devices into the SolarWinds Orion database for monitoring.

If the external gateway, external IP address, or external mask are set to 0.0.0.0, edit them with values valid for external devices.

To select the proper view we use the existing View By Device Type feature.

To ensure that Standard Poller does not overwrite MachineType and other fields, we use EntityType to identify UCS node in the Standard Poller (and so force Standard Poller not to overwrite our required fields). This same mechanism is also used for the ESX VMWare API.

  1. Confirm that LDAP authentication is not enabled on your UCS device. See the device documentation for details.
  2. Verify in the UCS console that the fiber connects have external IP addresses.
  3. Add the UCS Master node to the database.

    If the node shows up in the All Nodes list in italics or with "n/a" as the state, click on it, and click Yes to add the device.

    1. Click Manage Nodes in the All Nodes resource if the node is not in the list.
    2. Click Add Node. Provide the IP Address, or provide the host name and select Dynamic IP Address.
    3. Select External Node or Status Only: ICMP as the polling method.
    4. Select UCS Manager Credentials, and provide the credentials.
      • Polling Engine
      • UCS Port
      • UCS User Name
      • UCS Password
    5. Click Test under the UCS fields, and click Next.
    6. Select the resources to monitor on the node.
    7. Add relevant pollers.
    8. Review your information, and click OK, Add Node.
  4. Add each UCS fabric interconnect switch and blade device. Repeat step 3 for each device.
  5. Double-click on the UCS Master node in All Node, and find the UCS Overview resource.
  6. If any UCS device shown in the UCS Overview is not currently managed, double-click the device, and add the node.
 