Overview

The PerfStack page is grayed out when opened in the Orion Web Console.

Environment

SAM 6.4

Cause 

The Forms Authentication option is disabled and this is causing authentication issues in IIS.

Resolution

  1. Establish a remote desktop connection to the Orion server.
  2. Open Inetmgr.
  3. Click and expand Server in the left-hand pane.
  4. Click and expand Sites.
  5. Double-click Authentication.
  6. Enable Forms Authentication.

 

Disclaimer: Please note, any content posted herein is provided as a suggestion or recommendation to you for your internal use. This is not part of the SolarWinds software or documentation that you purchased from SolarWinds, and the information set forth herein may come from third parties. Your organization should internally review and assess to what extent, if any, such custom scripts or recommendations will be incorporated into your environment.  You elect to use third party content at your own risk, and you will be solely responsible for the incorporation of the same, if any.

 