HTTP 500 error when opening the Web Console

Created by Zoltán Jalsovszky, last modified by MindTouch on Jun 23, 2016

Views: 4,793 Votes: 2 Revisions: 5

Overview

This article describes the issue when you receive a blank page and an HTTP 500 error when trying to open the Web Console.

Environment

  • All versions of SAM
  • All versions of NPM

Cause 

This issue can occur because the IIS Application Pool not running correctly.

Resolution

  1. Open IIS Manager on the primary Orion server.
  2. Click Websites.
  3. Stop the SolarWinds NetPerfMon Website.
  4. Go to Application Pools, and stop the SolarWinds Orion Application Pool.
  5. Rerun the SolarWinds Orion Application Pool.
  6. Go back to Websites, and start the SolarWinds NetPerfMon Website.

 

Optional Resolution

  1. Run the Orion Permission Checker
  2. Fix any permissions that failed here, especially if they point to C:\inetpub\solarwinds
  3. Restart services with Orion Service Manager
  4. Try to access the SolarWinds NetPerfMon Website

 

 