Change management in IT is critical. But, even with a good change management process, changes are too often not correctly tracked, if at all. The configuration of your servers and applications is a key factor in their performance, availability, and security. Many incidents can be tracked back to an authorized (and sometimes unauthorized) configuration change, whether to a system file, configuration file, or Windows® Registry entry. Join SolarWinds VP of product management Brandon Shopp to discover how the new SolarWinds® Server Configuration Monitor is designed to help you.

Register now.

Home > Success Center > Server & Application Monitor (SAM) > SAM - Knowledgebase Articles > Error: Arithmetic overflow error converting numeric to data type numeric

Error: Arithmetic overflow error converting numeric to data type numeric

Overview

This article provides steps to resolve the following error:

Arithmetic overflow error converting numeric to data type numeric.

Environment

All SAM versions

Cause

The error is caused by invalid historical data in the database stored by a previous version of SAM.

Resolution

Warning: SolarWinds strongly recommends that you create a full backup of your database. The following steps may create permanent changes to your database.

1.Create a backup of your database. 

2. Run the following SQL command on your Orion database:

UPDATE APM_ProcessEvidence_Detail SET PercentCPU = NULL WHERE PercentCPU < 0

3. Re-run your maintenance manually. 