Submit a ticketCall us

AnnouncementUpgrading SolarWinds Orion Platform products has never been easier!

The SolarWinds Orion Installer is an all-in-one application for installations and upgrades. You use one installer to install or upgrade multiple Orion Platform products and install or upgrade Additional Polling Engines, Additional Web Servers, and High Availability Servers.

Learn more in the SolarWinds Orion Installer.

Home > Success Center > Server & Application Monitor (SAM) > SAM - Knowledgebase Articles > Access Denied: WinRM has exceed the number of user connections allowed

Access Denied: WinRM has exceed the number of user connections allowed

Overview

Access Denied: WinRM has exceed the number of user connections allowed.

Environment

All SAM versions

Resolution

Open either command prompt or PowerShell session in Administrator context
To view the WinRS settings, type:
In CLI: winrm get winrm/config/winrs
In PS: Get-Item WSMan:\localhost\Shell* | Select-Object Name,Value

To modify MaxConcurrentUsers, type:
In CLI: winrm set winrm/config/winrs @{MaxConcurrentUsers = "#"}
In PS: Set-Item WSMan:\localhost\Shell\MaxConcurrentUsers #

To modify MaxShellsPerUser, type:
In CLI: winrm set winrm/config/winrs @{MaxShellsPerUser="#"}
In PS: Set-Item WSMan:\localhost\Shell\MaxShellsPerUser #

To modify MaxMemoryPerShell, type:
In CLI: winrm set winrm/config/winrs @{MaxMemoryPerShellMB="#"}
In PS: Set-Item WSMan:\localhost\Shell\MaxMemoryPerShellMB #

 