The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Server & Application Monitor (SAM) > AppInsight for SQL error: The process was not found

AppInsight for SQL error: The process was not found

Created by Interspire Import, last modified by Steven Bansil_ret on Dec 01, 2016

Views: 130 Votes: 0 Revisions: 15

Overview

This article provides brief information and steps to resolve the issue when instances show that the SQL Server/SQL Agent is down with following error :

The process was not found.


All other meters and charts on the page are showing data collection and it is just the actual services that are not being found resulting to SQL servers showing errors.

Environment

SAM version 6.0 and later

Cause

The error is caused when the Debug program security setting was modified and the account used for polling is not part of the Administrators group.

 

This error can also be caused by a broken 32-bit WMI Class.

Resolution

 

Solution 1

  1. Go to Local Security Settings.
  2. Under Security Settings in the console tree, expand Local Policies and select User Rights Assignment.
  3. Click Debug programs on the right pane and change the Security Setting to Administrators.6311_1.jpg
  4. Re-try the polling process.

 

 

Solution 2

  1. Open the problematic AppInsight for SQL application in the web console.
  2. Click Edit Application.
  3. Change Platform to run polling job on from x86 to x64. 
  4. Submit the changes.