Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Patch Manager > Structured Exception Error 0x80004005 when publishing a package

Structured Exception Error 0x80004005 when publishing a package

Updated July 14, 2017

Overview

Structured Exception Error 0x80004005 is returned when publishing a package to WSUS.

Environment

All Patch Manager versions

 

Resolution

Solution 1:

Reboot the Patch Manager server.

 

Solution 2:

Check the Patch manager console logs in C:\ProgramData\Solarwinds\PM\Log\EminentWare.UI.Console.MMC for any access denied errors for the console account.

If there are multiple access denied errors, make sure the PM console account is not locked or the password expired. If you had to update the password then don't forget to update the password in credentials ring in SPM Console.

Solution 3 (not verified):

https://social.technet.microsoft.com...x80004005.aspx

 
Solution 4:
Solutions 1, 2 and 3 did not help and there were no access denied errors in any of the PM logs.
PM 2.1.5 and WSUS (Server 2012 R2) on same server.
Made sure in Credentials ring rules, the user account mapped to WSUS server has required privileges. In this case,
1. EWDGS was running with - domain\serviceaccount
2. Credentials Rules for WSUS configured to use local admin account
3. PM console was logged as Domain admin account
 
After changing the account used in step 2 to the same account as step 1 issue resolved.

 

Last modified

Tags

Classifications