Announcing NCM 7.7
With NCM 7.7, you can examine the rules that make up an access control list for a Cisco ASA device. Then you can apply filters to display only rules that meet the specified criteria, order the rules by line number or by the hit count, and much more.
See new features and improvements.

Home > Success Center > Patch Manager > Service cannot be started. System.Exception: Incorrect syntax near TRIPLE_DES

Service cannot be started. System.Exception: Incorrect syntax near TRIPLE_DES

Updated February 24, 2017

Overview

The following error occurs when restarting the EminentWare service after performing a backup and restore of the EminentWare databaseto SQL Server 2016 from an older version:

Service cannot be started. System.Exception: Incorrect syntax near 'TRIPLE_DES'.
at EminentWare.DataGridService.DataGridService.OnStart(String[] args)
at System.ServiceProcess.ServiceBase.ServiceQueuedMainCallback(Object state)

Environment

  • Patch Manager version 2.1.3
  • SQL server 2016

Cause 

TRIPLE_DES is deprecated in SQL Server 2016 and as of SPM 2.1.3 we only support SQL server 2014 and earlier.

Resolution

Workaround:

  1. Change the compatibility of EminentWare DB to SQL Server 2014 mode.
  2. Start the EminentWare Data Grid Service.
  3. Patch Manager should now be working.

 