In this video broadcast, Head Geek™ Tom LaRock is joined by Karen Lopez, Tim Chapman, and David Klee. They’ve known each other for many years, so this discussion was like four friends getting together to talk data and databases. They discussed diagnostic data collection, common performance root causes, reactive tuning versus proactive, and more. Join us for an engaging discussion on these topics! Plus, Tom LaRock will be available to answer your questions live.

Register now.

Home > Success Center > Orion Platform > Orion - Knowledgebase Articles > Set a plain-text password in the connection string

Set a plain-text password in the connection string

Table of contents

Updated March 15, 2018

Overview

This article describes how to change the encrypted password to plain-text in the connection string used by the Orion Platform.

Environment

  • Orion Platform

Steps

  1. Stop all Orion services using the Orion Service Manager.
  2. Navigate to the Orion directory.
    The default location is: 
    C:\Program Files (x86)\SolarWinds\Orion\
  3. Open the SWNetPerfMon.DB file in a text editor (such as Notepad). 
  4. Replace:
    Encrypted.Password="..."

    with

    Password='YOUR-PASSWORD-HERE'
  5. Save the file.
  6. Start all Orion services using the Orion Service Manager.

 

 