Virtualization can give you enormous flexibility with future workloads and can be a key enabler for other areas, like cloud computing and disaster recovery. So, how can you get a handle on the performance challenges in your virtual environment and manage deployments without erasing the potential upside? Learn the four key areas you need to be focusing on to help deliver a healthy and well-performing data center.

Get your free white paper.

Home > Success Center > Orion Platform > Orion - Knowledgebase Articles > InformationService.log displays a SolarWinds.Alerting.Service.exe error

InformationService.log displays a SolarWinds.Alerting.Service.exe error

Updated February 26, 2018

Overview

A message similar to the following is recorded in the ./v3.0/ InformationService.log file:

2018-01-10 09:21:49,899 [126] ERROR SolarWinds.InformationService.Core.InformationService -
olarWinds.Alerting.Service| SolarWinds.Alerting.Service.exe|
SolarWinds.Orion.Core.Alerting.Plugins.Conditions.Swql.ConditionEvaluatorSwql.ExecuteQuery()| (null)
Exception caught in method SolarWinds.InformationService.Core.InformationService.Query
System.Data.SqlClient.SqlException (0x80131904): Divide by zero error encountered. 

Environment

  • All Orion versions

Cause 

The alert cannot be evaluated properly.

Resolution

  1. Look in the ProgramData\SolarWinds\Logs\Orion\Alerting.Service.V2.log file to locate and disable the alert that could be causing the problem.
  2. Verify that the message is cleared.
    If the error is not cleared:
    1. Recreate the alert from scratch.
    2. Build the alert condition to narrow down the location of the problem.
 

 