2018 is the seventh year for THWACKcamp™, and once again we’ll be live October 17 – 18 with packed session tracks covering everything from network monitoring and management, to change control, application management, storage, cloud and DevOps, security, automation, virtualization, mapping, logging, and more.

Register for online sessions.

Home > Success Center > Orion Platform > Orion - Knowledgebase Articles > ERROR: INFO  SolarWinds.Orion.Common.SWEventLogging - IPv6 TCP Listening Disabled

ERROR: INFO  SolarWinds.Orion.Common.SWEventLogging - IPv6 TCP Listening Disabled

Created by Jeremy Holmes, last modified by MindTouch on Jun 23, 2016

Views: 1,561 Votes: 0 Revisions: 3

Overview

The Syslog Service is not starting on a Solarwinds server.

 

2016-03-11 14:42:26,047 [StartupThread] INFO  SolarWinds.Orion.Common.SWEventLogging - IPv6 TCP Listening Disabled
2016-03-11 14:42:26,047 [UDPListenerThreadIpv6] INFO  SolarWinds.Orion.Common.SWEventLogging - Syslog Collector Started on :: IPv6 UDP Port 514
2016-03-11 14:42:26,063 [UDPListenerThread] ERROR SolarWinds.Orion.Common.SWEventLogging - Syslog Service Unhandled Exception Only one usage of each socket address (protocol/network address/port) is normally permitted
   at System.Net.Sockets.Socket.DoBind(EndPoint endPointSnapshot, SocketAddress socketAddress)
   at System.Net.Sockets.Socket.Bind(EndPoint localEP)
   at System.Net.Sockets.UdpClient..ctor(IPEndPoint localEP)
   at SolarWinds.Syslog.UdpPacketListener`1.ListenForSyslogPackets(Boolean isIpv6, IPEndPoint localEndPoint, IRunState runState)
   at SyslogService.SyslogService.ListenForUDPPacket(Object ipv6)
   at System.Threading.ThreadHelper.ThreadStart_Context(Object state)
   at System.Threading.ExecutionContext.RunInternal(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
   at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
   at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)
   at System.Threading.ThreadHelper.ThreadStart(Object obj)

Environment

Orion 2013 and later

Cause 

This is due to a port conflict with another Syslog Service such as Kiwi.

 

Resolution

  • Disable the other Service or Application, per steps of that product, that is using the port (UDP 514).