Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Orion Platform > Cannot execute the external program or visual basic script alert actions

Cannot execute the external program or visual basic script alert actions

Updated September 27, 2017

Overview

When using a non-local user, including domain administrators, you cannot validate the credentials used to run the script.

You receive an error similar to one of the following when your credentials are validated:

Check 'Replace a process level token' account privilege of user which runs SolarWinds Orion Module Engine service.

Verify that the 'Replace a process level token' account privilege is selected on the user account that runs the SolarWinds Orion Module Engine service.

Environment

Any product that runs on Orion Platform 2016.1 or later, such as:

  • NPM 12.0 and later
  • SAM 6.3 and later

Cause 

The account does not have sufficient privileges to run the script.

Resolution

  1. Log on as and administrator to the Orion server.
  2. Add the user to the local administrator group.
    • Local users - add them to the local administrators group.
    • Domain users - add them to the domain administrators group.
  3. Navigate to Settings > Windows settings > Security settings > Local policies > Security options.
  4. Disable User Account Control: Run all administrators in Admin Approval Mode.
  5. Restart the server.

Repeat these steps for every server that runs a script.

 

 

 

 