Overview

This article provides information on incorrectly shown interface names for Juniper devices.

Environment

  • All NTM versions
  • Juniper Networks, Inc. ex4300-24p Ethernet Switch, kernel JUNOS 13.2X51-D30.4, Build date: 2014-11-27 13:28:00 UTC

Cause 

Issue has been identified by our Devs to be on a device:

Juniper devices by default in LLDP table lldpRemLocalPortNum (1.0.8802.1.1.2.1.4.1.1.2) return local interface index instead of port number.

Resolution

Contact the vendor (Juniper) and seek further assistance or refer to the below resource:

 

https://www.juniper.net/documentation/en_US/junos15.1/topics/reference/configuration-statement/port-id-subtype-edit-protocols-lldp.html

 