Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Network Performance Monitor (NPM) > VM Reports on additional Web server fail to run

VM Reports on additional Web server fail to run

Created by Robert Stidman, last modified by MindTouch on Jun 23, 2016

Views: 12 Votes: 0 Revisions: 5

Overview

The following error appears when running VM Reports from the additional Web server:
Error setting up report cell during initialization 'Custom Table.'
Data presenter vim.image.managedstatus.watermark not found.

Running the reports from the main Orion server does not yield an error.

Environment

Orion Core versions later than 2015.x.x

Cause 

This occurs when VIM Web files are missing from the additional Web server. 

Resolution

  1. Copy the following files from the main website to the additional website:
    • c:\Program Files (x86)\SolarWinds\Orion\Schemas\ApplicationTypes\vim.apptypes.xml
    • c:\Program Files (x86)\SolarWinds\Orion\Schemas\Presenters\vim.presenters.xml
    • c:\Program Files (x86)\SolarWinds\Orion\Schemas\Transformers\vim.transformers.xml
  2. Open an admin command prompt on the additional and run iisreset, and try again to run the report.

 