Change management in IT is critical. But, even with a good change management process, changes are too often not correctly tracked, if at all. The configuration of your servers and applications is a key factor in their performance, availability, and security. Many incidents can be tracked back to an authorized (and sometimes unauthorized) configuration change, whether to a system file, configuration file, or Windows® Registry entry. Join SolarWinds VP of product management Brandon Shopp to discover how the new SolarWinds® Server Configuration Monitor is designed to help you.

Register now.

Home > Success Center > Network Performance Monitor (NPM) > Unexpected website error is displayed when editing virtualization thresholds

Unexpected website error is displayed when editing virtualization thresholds

Updated April 18, 2017

Overview

An unexpected website error is displayed when editing virtualization thresholds.

Environment

NPM 12.0.1

Cause 

This occurs when the DLL file is corrupted or in the VIM folder.

Resolution

  1. Stop all Orion services.
  2. Back up the following DLL file to a separate location and delete it from the original location:
    C:\Program Files (x86)\SolarWinds\Orion\VIM\SolarWinds.Common.dll
  3. Start all Orion services.
  4. Edit the virtualization thresholds and verify that no errors are displayed.

 

If the issue persists, perform the following:

  1. Stop all Orion services.
  2. Back up the following DLL file to a separate location and delete it from the original location:
    C:\Program Files (x86)\SolarWinds\Orion\VIM\SolarWinds.Common.dll
  3. Copy the C:\Program Files (x86)\SolarWinds\Orion\SolarWinds.Common.dll file to the following folder:
    C:\Program Files (x86)\SolarWinds\Orion\VIM
  4. Start all Orion services.
  5. Edit the virtualization thresholds and verify that no errors are displayed.

 

 

 