The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > Troubleshooting errors with reports created in the web console

Troubleshooting errors with reports created in the web console

Table of contents
No headers
Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 202 Votes: 1 Revisions: 8

This article addresses errors that may occur when generating reports in the web console.

Issue:
Error setting up report cell during rendering 'Custom Table'
Error executing SQL: Invalid column name 'ColumnName'
Resolution:
Attempting to create a report using a non-existent custom property will trigger this error. Typically, this can occur when a custom property that is used to initially define a report is later removed in an unrelated operation.
To correct this error: Restore the missing custom property (invalid column name). For more information, see "Creating Custom Properties" in the SolarWinds Orion NPM Administrator Guide.
Issue:
Error setting up report cell during rendering 'Custom Table'
Missing field 'ColumnName' in Orion.NodesCustomProperties
Resolution:
Attempting to create a report using a non-existent custom property will trigger this error. Typically, this can occur when a custom property that is used to initially define a report is later removed in an unrelated operation.
To correct this error: Restore the missing custom property (missing field). For more information, see "Creating Custom Properties" in the SolarWinds Orion NPM Administrator Guide.