Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Network Performance Monitor (NPM) > The Configuration Wizard says that website configuration has failed due to a failure updating ASP.NET script maps

The Configuration Wizard says that website configuration has failed due to a failure updating ASP.NET script maps

Table of contents
No headers
Created by Interspire Import, last modified by Brian Collins on Jan 04, 2017

Views: 265 Votes: 3 Revisions: 8

Updated on:

 

While completing the Configuration Wizard, I see the following error:
Website configuration failed:

  • Failure updating ASP.NET script maps

The ASP.NET script mapping must be updated, as indicated in the following procedure:

  1. If you are installing Orion NPM on a 32-bit server, complete the following steps:
    1. Open a command prompt (Start > All Programs > Accessories >Command Prompt).
    2. Browse to Volume:\WINDOWS\Microsoft.net\Framework\v4.0.30319\ (enter cd Volume:\WINDOWS\Microsoft.net\Framework\v4.0.30319\), where Volume: is the volume on which you have installed your local operating system. Typically, this is C:.
    3. At the prompt, enter aspnet_regiis -i
    4. Run the Configuration Wizard again (Start > All Programs > SolarWinds Orion > Configuration and Auto-Discovery > Configuration Wizard).
  2. If you are installing Orion NPM on a 64-bit server, complete the following steps:
    1. Open a command prompt (Start > All Programs > Accessories >Command Prompt).
    2. Browse to Volume:C:\InetPub\AdminScripts\ (enter cd Volume:C:\InetPub\AdminScripts\), where Volume: is the volume on which you have installed your local operating system. Typically, this is C:.
    3. At the prompt, enter cscript.exe adsutil.vbs set W3SVC/AppPools/Enable32BitAppOnWin64 true
    4. On the same volume, browse to Volume:\WINDOWS\Microsoft.net\Framework\v4.0.30319\ (enter cd Volume:\WINDOWS\Microsoft.net\Framework\v4.0.30319\).
    5. At the prompt, enter aspnet_regiis -i
    6. Run the Configuration Wizard again (Start > All Programs > SolarWinds Orion > Configuration and Auto-Discovery > Configuration Wizard).