Submit a ticketCall us

Announcing NCM 7.7
With NCM 7.7, you can examine the rules that make up an access control list for a Cisco ASA device. Then you can apply filters to display only rules that meet the specified criteria, order the rules by line number or by the hit count, and much more.
See new features and improvements.

Home > Success Center > Network Performance Monitor (NPM) > SolarWinds server regularly crashes

SolarWinds server regularly crashes

Table of contents
EOF expected: /content/body/div/pre[1], line 1, column 12 (click for details)

Overview

This article provides steps on how to troubleshoot when Orion SolarWinds server crashes regularly.

Environment

All versions NPM

Steps

Look for the following error and then do the procedure below:

 

Core.BusinessLayer.log

ERROR SolarWinds.Orion.Core.BusinessLayer.CoreBusinessLayerPlugin - Error configuring Job Engine
System.ApplicationException: Could not reach JobScheduler service after 1 retries
   at SolarWinds.Orion.Core.BusinessLayer.JobScheduler.ExecuteJobSchedulerOperation[T](String operationName, JobSchedulerOperation`1 operation, Boolean retryOnError)
   at SolarWinds.Orion.Core.BusinessLayer.JobScheduler.ExecutionEngineExists(Uri executionEngineUri)
   at SolarWinds.Orion.Core.BusinessLayer.CoreBusinessLayerPlugin.ConfigureJobEngine()

PollingController.log

ERROR SolarWinds.Collector.PollingController.JobSchedulerEventsService - Error removing job a7c62097-8f1c-4db1-828e-60f603858228.
System.TimeoutException: The request operation did not complete within the allotted timeout of 00:03:00. The time allotted to this operation may have been a portion of a longer timeout. ---> System.TimeoutException: Request timed out after 00:03:00 while establishing a transport connection to net.pipe://localhost/solarwinds/jobengine/router. The time allotted to this operation may have been a portion of a longer timeout. ---> System.TimeoutException: Cannot connect to endpoint 

 

1. Stop all Orion services.

2. Go to: C:\ProgramData\Solarwinds\Installers.

3. Uninstall and re-install the following (These 3 services are responsible for collecting data):

  • CollectorInstaller
  • JobEngine
  • JobEngine.v2

4. Start all Orion Services.

5. Restart IIS.

6. Run Configuration Wizard.

 

Last modified
23:36, 22 Jun 2016

Tags

Classifications

Public