Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > Network Performance Monitor (NPM) > Setting the Node Warning Level in Network Performance Monitor

Setting the Node Warning Level in Network Performance Monitor

Table of contents
Created by Erin Stenzel, last modified by MindTouch on Jun 23, 2016

Views: 35 Votes: 0 Revisions: 3

Overview

A device may drop packets or fail to respond to a poll for many reasons. Should the device fail to respond, the device status is changed from Up to Warning. On the Orion Polling Settings view, you can specify the Node Warning Level, which is the length of time a device is allowed to remain in the Warning status before it is marked as Down. During the interval specified, the service performs "fast polling" (ICMP) to continually check the node status.

 

Note: You may see events or receive alerts for down nodes that are not actually down. This can be caused by intermittent packet loss on the network. Set the Node Warning Interval to a higher value to avoid these false notifications. For more information, see “Managing Packet Loss Reporting”.

Environment

  • Orion NPM 10.0
  • Orion NPM 10.1
  • Orion NPM 10.1.1

Steps

To set the Node Warning Level:

  1. Log in to the Orion Web Console using an account with administrative rights.
  2. Click Settings in the upper right of the web console, and then click Polling Settings in the Settings group of the Orion Website Administration view.
  3. In the Calculations and Thresholds group, set the Node Warning Level to an appropriate interval, in seconds. 
    Note: The default Node Warning Level interval is 120 seconds.
  4. Click Submit.

 

 

 

Last modified
23:32, 22 Jun 2016

Tags

Classifications

Public