Overview

SNMPv3 Nodes displaying the following error message on some Orion Polling Engines while attempting to run a SNMP walk on the SNMPv3 device:

 

Error 31224 Crypto Error - Unable to perform the requested algorithm.

If FIPS restristions are enabled, please select a FIPS compliant algorithm.


Also, ​Alerting Action fails for some of the trigger actions 
Execute program : "D:\Program Files (x86)\SolarWinds\Orion\APM\SolarWinds.APM.RealTimeProcessPoller.exe

Environment

  • NPM 11.5.2
  • SAM 6.2.2
  • NTA 3.11
  • IPAM 4.3.0  
  • WPM 2.2
  • 9 Orion Polling Engines
  • Microsoft Windows Server 2008 R2 Enterprise
  • 274 Hotfix(s) Installed

Cause 

The working Additional Polling Engine has:                                                                                                                                            

  • C:\Program Files (x86)\Common Files\SolarWinds\OpenSSL\x64\libeay32.dll = Version 1.0.2.1

The working Additional Polling Engine has:                                                                                                                                            

  • C:\Program Files (x86)\Common Files\SolarWinds\OpenSSL\x64\libeay32.dll = Version 1.0.2.4
     

Resolution

Warning: Consult your System Administrator before performing the following procedure. 

 

  1. Stop the Orion Services on Non Working Poller using the Orion Service Manager.

  2. Back up the Open SSL folder located at C:\Program Files (x86)\Common Files\SolarWinds\OpenSSL.
  3. Delete both the x86 and 64 folders.
  4. Copy the same folder from the working poller to the non working poller in same location, both the x86 and 64 folders.
  5. Restart all Orion Services using the Orion Service Manager.
Last modified
23:34, 22 Jun 2016

Tags

Classifications

Public