The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > Run-time error 339 when opening Syslog Viewer or Trap Viewer

Run-time error 339 when opening Syslog Viewer or Trap Viewer

Table of contents
No headers
Created by Interspire Import, last modified by Carlos Vigier on Jun 16, 2017

Views: 324 Votes: 1 Revisions: 15

Issue:

The following error occurs when opening 'Syslog Viewer' and 'Trap Viewer'.

"Run-time error '339'. Component 'InnovaDSXP2.ocx' or one of its dependencies not correctly registered: a file is missing or invalid" 

Cause:

The file named 'InnovaDSXP2.ocx' was missing or invalid.

Resolution:

  1. Run a repair on the Core Services - Repairing Orion Core Services.
  2. Click Start > Run > cmd > Type regsvr32 'C:\Program Files (x86)\Common Files\SolarWinds\InnovaDSXP2.ocx' 
  3. This error can also happen if the antivirus is blocking the file. Please verify antivirus exclusions are implemented. 

 

https://support.solarwinds.com/Succe...ory_exclusions

 

*For 64-Bit version of the OS you may need to go to folder C:\Windows\SysWOW64 in the command line and run the regsrv32 program from there and opposed to the default regsrv32 program found in C:\Windows\system32. Check the path in the command line to find what program the command prompt defaults to.

** You may also need to unregistered the file and re-register it. Use the u parameter to unregistered the file (i.g. regsvr32 /u 'C:\Program Files (x86)\Common Files\SolarWinds\InnovaDSXP2.ocx'