Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > Replace the Polling Collector

Replace the Polling Collector

Table of contents
Created by Panagiotis.Pavlos.Michailidis, last modified by MindTouch Content Copy on Nov 13, 2015

Views: 48 Votes: 2 Revisions: 5

Overview

This article details how to replace the Polling Collector.

Environment

  • NPM version 11.5.2
  • Windows Server 2008
  • Windows Server 2003

Steps

  1. Click Start > All Programs > SolarWinds Orion > Advanced Features > Orion Services Manager.
     
  2. Stop all SolarWinds services in the Orion Services Manager.
     
  3. Rename the current PollingController.sdf file as PollingController_sdf.old.
    Note: The default location of the PollingController.sdf file:
    * Windows Server 2003 - C:\Documents and Settings\All Users\Application Data\SolarWinds\Collector\Data\
    * Windows Server 2008 - C:\ProgramData\SolarWinds\Collector\Data\

     
  4. Create a copy of PollingController - Blank.sdf, and then rename the copy as PollingController.sdf.
    Note: The default location of the PollingController - Blank.sdf file.
    * Windows Server 2003 - C:\Documents and Settings\All Users\Application Data\SolarWinds\Collector\Data\
    * Windows Server 2008 - C:\ProgramData\SolarWinds\Collector\Data\

     
  5. Right-click the new PollingController.sdf, and then click Properties.
     
  6. Clear the Read-only box, and then click OK.
     
  7. Restart all SolarWinds services in the Orion Services Manager.

 

 