The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > Percent Utilization - Line Chart: Data is not available

Percent Utilization - Line Chart: Data is not available

Created by Malik Haider, last modified by Craig Healy on Feb 14, 2017

Views: 137 Votes: 1 Revisions: 7

Overview

The following error appears in Orion when attempting to display a Line Chart for Percent Utilization for one or more interfaces:

Data is not available

 

percent.PNG

 

There is also no Interface Bandwidth listed for the same interface:

 

intft.PNG

 

Environment

NPM 11 and later

Cause 

The ifSpeed value is missing from the device OIDs.  The Interface must provide ifSpeed under the device OIDs and only then can the Interface bandwidth and utilization be calculated based on the provided values .

The following is an example where two of the interfaces are missing the ifSpeed value:

 

.1.3.6.1.2.1.2.2.1.5.2 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.2 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.3 = GAUGE32: 100000000

.1.3.6.1.2.1.2.2.1.2.3 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.4 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.4 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.5 = GAUGE32: 100000000

.1.3.6.1.2.1.2.2.1.2.5 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.6 = GAUGE32: 100000000

.1.3.6.1.2.1.2.2.1.2.6 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.7 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.7 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.8 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.8 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.9 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.9 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.10 = GAUGE32: 0

.1.3.6.1.2.1.2.2.1.2.10 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.11 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.11 = STRING: "Adaptive Security Appliance '

.1.3.6.1.2.1.2.2.1.5.12 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.12 = STRING: "Adaptive Security Appliance 'GigabitEthernet1/3' interface"

.1.3.6.1.2.1.2.2.1.5.13 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.13 = STRING: "Adaptive Security Appliance 'GigabitEthernet1/4' interface"

.1.3.6.1.2.1.2.2.1.5.14 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.14 = STRING: "Adaptive Security Appliance 'GigabitEthernet1/5' interface"

.1.3.6.1.2.1.2.2.1.5.15 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.15 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.16 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.16 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.17 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.17 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.18 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.18 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.19 = GAUGE32: 0

.1.3.6.1.2.1.2.2.1.2.19 = STRING: "Adaptive Security Appliance

.1.3.6.1.2.1.2.2.1.5.20 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.20 = STRING: "Adaptive Security Appliance '

.1.3.6.1.2.1.2.2.1.5.21 = GAUGE32: 1000000000

.1.3.6.1.2.1.2.2.1.2.21 = STRING: "Adaptive Security Appliance

 

Resolution

  1. On the Interface Details page, click Edit Interface.

  2. Set the values for the following:

    • Transmit Bandwidth: 100 Mb/s

    • Receive Bandwidth: 100 Mb/s