Issue:

Interface Polling has stopped. SolarWinds Collector Service will not load due to SolarWinds.Collector.Contract.dll.

Error generated:

Collector.BusinessLayer.log 
System.TypeLoadException: Could not load type 'SolarWinds.Collector.Contract.IProcessingPlan' from assembly 'SolarWinds.Collector.Contract, Version=2.4.0.180, Culture=neutral, PublicKeyToken=null'.

Resolution:

Upgrade to Orion 10.6. The SolarWinds.Collector.Contract.dll that comes with Orion 10.6 is a newer version that resolves this issue.
 