Views: 901 Votes: 0 Revisions: 8

Issue:

Nodes that were initially monitored by a SolarWinds environment that did not include NPM are not automatically polled for NPM-specific information (e.g. wireless, EnergyWise, VSAN data, etc.) after NPM is installed.

Resolution:

After NPM is installed, select desired pollers using Node Management, as follows:

  1. Log in to the Orion Web Console using an account with administrative privileges.
  2. Click Settings in the top right corner.
  3. Click Manage Nodes in the Node & Group Management section.
  4. For each node that is not polled completely, complete the following steps:
    1. Check the node that is not polled completely.
    2. Click List Resources.
    3. Confirm that all required pollers are checked.
    4. Click Submit.

 

This article applies to all SolarWinds NPM installations.