Unable to scan existing Images. see NcmBusinessLayerPlugin.log for details

Updated

Overview

 

NcmBusinessLayerplugin log


ERROR SolarWinds.Cirrus.BusinessLayer.FirmwareUpgrade.FirmwareRepositoryWatcher - FileSystemWatcher Created errorSystem.ServiceModel.FaultException`1[SolarWinds.InformationService.Contract2.InfoServiceFaultContract]: Create failed, check fault information.
The target table 'dbo.NCM_FirmwareUpgradeImages' of the DML statement cannot have any enabled triggers if the statement contains an OUTPUT clause without INTO clause. (Fault Detail is equal to InfoServiceFaultContract [ System.Data.SqlClient.SqlException (0x80131904): The target table 'dbo.NCM_FirmwareUpgradeImages' of the DML statement cannot have any enabled triggers if the statement contains an OUTPUT clause without INTO clause.

 

Error scanning firmware repository

Environment

  • NCM 7.6

 

Cause 

 

 Trigger to NCM_FirmwareUpgradeImages table was added which is not allowed

Resolution

1.Run MS SQL Management Studio 
2.Go to NCM_FirmwareUpgradeImages table -> Triggers. 
3.Select the trigger(s) and disabled it, if that will not help then delete it. Restart all services in Orion service manager.

 

 

 

 