The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > NPM Installation Guide > Integrate NPM with an existing Orion Platform product

Integrate NPM with an existing Orion Platform product

Table of contents
No headers

Updated: September 21, 2017

If you have SolarWinds Network Performance Monitor 12.0 or later, use the SolarWinds Orion Installer to upgrade and integrate NPM  with an existing Orion Platform. For earlier NPM versions, follow the steps below.

To integrate SolarWinds Network Performance Monitor with an existing Orion Platform, you may need to install the stand-alone product onto the Orion server and perform additional steps. These instructions walk-through the specific installation steps, Configuration wizard selections, and any additional licensing and integration options to select.

Consider these guidelines for your installation:

  • When integrating with the existing Orion SQL database, the user account needs only to be in the db_owner database role for the existing database.
  • For advanced configuration requirements and steps such as FIPS, see the Administrator Guide.
  • If you have High Availability as part of your Orion Platform installation, review Install SolarWinds NPM with High Availability
  • Install NPM on the Orion server with other products including NCM, SAM, and SRM.
  • Installing products on the same server provides a single pane of glass for monitoring: consolidates polling calls and traffic through polling methods, stores and tracks nodes in one system without cross-referencing, provides data for alerts and reports on one system, and manages all logic easily on one system.
  • Select the same Orion SQL database used by the current Orion Platform environment.
  • If you need to migrate Orion products and install NPM on a new server due to requirements, migrate the Orion products first.

Adding a new product into an existing Orion Platform may require upgrading the current products prior to the installation.

  • Using compatibility information and the SolarWinds Product Upgrade Advisor, determine if currently installed products must be upgraded prior to installing this product.
  • Depending on the upgrade path, upgrade products following the SolarWinds Upgrade Guide. When complete, install the new product following these instructions.
  • When preparing the server, review the multi-module system guidelines when installing into an existing Orion Platform.
File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0160-Uninstall_SolarWinds_NPM/checkbox.gif 1. Install the product

Follow the stand-alone installation instructions.

  1. Click Next on the Welcome window.

    The system scans the environment to ensure that the system requirements are met. If your system is not compatible, the installer provides a link to a knowledge base article with the resolution. When resolved, run the installation again.

  2. Select your preferred language.
  3. If the wizard detects that Microsoft Internet Information Services (IIS) is not installed, select the recommended option to continue and install IIS automatically.
  4. If the wizard detects that the Microsoft .Net framework is not installed, select the recommended option to continue and install it automatically.

    Downloading and installing Microsoft .NET Framework 4.5 can take more than 20 minutes. If your system reboots, run the installation again.

  5. If you agree, accept the terms of the license agreement.
  6. Accept the default directory, or click Browse and select a directory.
  7. Enable Quality of Experience (QoE) traffic monitoring.

    Enabling QoE installs an agent on the Orion Main Polling Engine. This agent collects packet-level traffic statistics, like network response time and application response time, for any application traffic it sees going to or from Orion. SolarWinds recommends that you enable QoE.

  8. Click Next to begin copying the files.

    Downloading and installing Microsoft .NET Framework 4.5 can take more than 20 minutes. If your system reboots, run the installation again.

    If you are using Microsoft Internet Explorer®, SolarWinds recommends you add the URL of your Orion website (http://FullOrionServerName/), the URL of SolarWinds support (http://solarwinds.com/support), and about:blank to the list of trusted sites.

File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0160-Uninstall_SolarWinds_NPM/checkbox.gif

2. Run the Configuration wizard

After the installation completes, the Configuration wizard automatically runs. If the Configuration wizard does not load automatically, start the Configuration wizard in the SolarWinds Orion > Configuration and Auto-Discovery program folder.

  1. In the Welcome dialog box, click Next.
  2. If prompted to stop services, click Yes.
  3. In the Database Settings dialog box, select an SQL Server and authentication method, and click Next.

    Use SQL Server Authentication to ensure the SolarWinds Orion server can always access SQL Server, even when hosted remotely on a separate server.

    File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0110-Integrate_NPM_with_an_existing_Orion_Platform_product/config-wizard-1.png

  4. In the Database Settings dialog box, select a database from Use an existing database, and click Next.
  5. In the Database Account dialog box, create an account or use an existing account that the polling engine and Web Console use to access the database, and click Next.
  6. In the Website Settings dialog box, complete selections for your installation:

    If you select Skip website binding, the Configuration Wizard does not make changes within the website configuration in your IIS. This option blocks IP address, port, and SSL certificate options.

    1. Select All Unassigned unless your environment requires a specific IP address for the Orion Web Console. The Port is 443 by default.
    2. Specify the Port and the Website Root Directory where the system installs the Web Console files.

      If you specify any port other than 80, include that port in the URL used to access the Web Console.

    3. To configure SSL, click Enable HTTPS and select your SSL certificate.

      If a certificate is not available, select the option to Generate Self-Signed Certificate. The Configuration Wizard automatically generates a self-signed certificate issued to the hostname or FQDN and adds it to the trusted certificate store.

      File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0110-Integrate_NPM_with_an_existing_Orion_Platform_product/ssl_self-signed_cert.png

  7. If prompted to create a directory or website, click Yes.
  8. Review the list of services to install, and click Next.
  9. Click Yes if prompted to disable the SNMP Trap Service and enable the SolarWinds Trap Service.
  10. In the Completing the Orion Configuration Wizard dialog box, click Next.
  11. If prompted to activate your installation, enter the License Key for your product noted from the SolarWinds Customer Portal.
  12. When completed, click Finish to launch the Orion Web Console.

    Click Start > All Programs > SolarWinds > Orion Web Console

    or

    Open a web browser on your Orion server and enter http://ipAddress or http://hostname, where ipAddress is the IP address of your server and hostname is the host name of your server.

  13. Log in with user name admin and leave the password field blank.

    For security purposes, SolarWinds recommends that you change the password to your admin account.

File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0160-Uninstall_SolarWinds_NPM/checkbox.gif 3. Install any available hotfixes (optional)

If the Customer Portal listed hotfixes for the product version you downloaded, run those installations.

  1. Download the zip file.
  2. Extract the zip files to the main polling engine or Orion server.
  3. Review the README for details on the release and further instructions.
  4. Run the installation file according to the README instructions.
File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0160-Uninstall_SolarWinds_NPM/checkbox.gif 4. Add license key

Add and activate the license key from the Customer Portal.

  1. Open the Orion Web Console in a web browser.

    Click Start > All Programs > SolarWinds > Orion Web Console

    or

    Open a web browser on your Orion server and enter http://ipAddress or http://hostname, where ipAddress is the IP address of your server and hostname is the host name of your server.

  2. Click Settings > All Settings > License Manager.
  3. Click Add/Upgrade License.
  4. Enter the Activation Key and Registration Information, and click Activate.

To activate an offline license, see Activate licenses offline.

File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0160-Uninstall_SolarWinds_NPM/checkbox.gif 5. Install on the additional polling engine (optional)

If you have an additional polling engine (APE), download and install the product using the Scalability Engine Installer.

  1. In the Orion Web Console, click Settings > All Settings > Polling Engines.
  2. Click the Download Installer Now and move the downloaded file to the additional polling engine server.
  3. Run the installation file. The steps should mirror the installation steps completed on the main polling engine server. During installation, select the option for Additional Polling Engine.
  4. To activate the license, access the Orion Web Console on the main polling engine or Orion server.

    Do not activate the license directly on the additional polling engine.

  5. Click Settings > All Settings > License Manager.
  6. Click Add/Upgrade License.
  7. Enter the Activation Key and Registration Information, and click Activate.
  8. You may need to assign the license to the additional polling engine.
    1. Click Assign.
    2. Select the additional polling engine and click Assign.
  9. Repeat these instructions for multiple additional polling engines.

Best Practice: If the product included hotfixes, you can also run those directly on the additional polling engines. The Scalability Engine Installer should have included them. If the hotfix installation states the fixes are already installed, do not continue. Otherwise, complete the installation instructions from the README file.

File:Success_Center/Reusable_content_-_InfoDev/NPM/reuse/0160-Uninstall_SolarWinds_NPM/checkbox.gif 6. Install on the additional web server (optional)

If you have an additional web server (AWS), download and install the product using the Scalability Engine Installer.

  1. In the Orion Web Console, click Settings > All Settings > Web Console Settings.
  2. Click the Download Installer Now and move the downloaded file to the additional polling engine server.
  3. Run the installation file. The steps should mirror the installation steps completed on the main polling engine server. During installation, select the option for Additional Web Server.
  4. To activate the license, access the Orion Web Console on the main polling engine or Orion server.

    Do not activate the license directly on the additional polling engine.

  5. Click Settings > All Settings > License Manager.
  6. Click Add/Upgrade License.
  7. Enter the Activation Key and Registration Information, and click Activate.
  8. You may need to assign the license to the additional web server.
    1. Click Assign.
    2. Select the additional web server and click Assign.

Best Practice: If the product included hotfixes, you can also run those directly on the additional web server. The Scalability Engine Installer should have included them. If the hotfix installation states the fixes are already installed, do not continue. Otherwise, complete the installation instructions from the README file.

 
Last modified

Tags

Classifications

Public