Overview

Only a limited number of series is displayed on a custom chart.

Environment

  • NPM versions earlier than v11.5
  • Orion Platform 2015.x

Cause 

The limits have been lowered to 10 series in the new charts for performance reasons.

Resolution

Perform any of the following options:

Add a new property (recommended)

  1. Go to the ResourceProperties table .
  2. Add a new property for a given ResourceID:
    PropertyName='chartmaxseries'
    PropertyValue='30

    Note: You can obtain the ResourceID from the URL when editing the chart.

Adjust the limit setting

  1. Open C:\Program Files (x86)\SolarWinds\Orion\web.config in a text editor.
  2. Locate the following line:
    <add key="MaximalNumberOfSeriesInChart" value="10" />
  3. Change the value to adjust the limit. 

 

 