Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Ubiquiti Networks devices show up as Frogfoot Networks devices

Ubiquiti Networks devices show up as Frogfoot Networks devices

Created by Daniel Polaske, last modified by MindTouch on Jun 23, 2016

Views: 3,767 Votes: 1 Revisions: 5

Overview

Certain devices show up as Frogfoot Networks devices.

Environment

All Orion environments

Cause 

When NPM polls the device via SNMP for OID 1.3.6.1.4.1 (the sysobjectID used to identify objects), the Ubiquiti returns a value of 100002, which is the sysobjectID publicly registered to FrogFootNetworks. This can be verified using the link:

http://www.iana.org/assignments/ente...rprise-numbers

10002
  Frogfoot Networks
    Johann L. Botha
      joe&frogfoot.net

With each release, all ID numbers are compiled in the above link into the SWDiscovery.cfg file in C:\Program Files\Solarwinds\.

Resolution

  • There are a few ways to approach this problem.  If, in fact, this is an oversight on Ubiquiti's part, you might first want to reach out to their support to confirm whether they intended to report the sysobjectID as shown above and let them know that it most likely needs to be changed to something like:

    41112

      Ubiquiti Networks, Inc.

        Kestutis Barkauskas

          keba&ubnt.com

  • One other way to mitigate this would be to import the custom poller from the thwack community below as a workaround (the article gives a guide on how to import the Device Studio Poller): https://thwack.solarwinds.com/docs/DOC-177857 ... http://www.solarwinds.com/documentat...0Studio|_____7

  • This can also be submitted as a standard feature request to be overwritten in subsequent versions.