Submit a ticketCall us

Training ClassThe Orion® Platform Instructor-led Classes

Provided by SolarWinds® Academy, these trainings will introduce users to the Orion Platform and its features, management, and navigation. These courses are suitable for users looking to discover new tips, tricks, and ways to adapt their Orion products to better suit their monitoring needs:
Deploying the Orion Platform
Configuring Orion views, maps, and accounts
Configuring Orion alerts and reports

Reserve your seat.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > The Socket connection was aborted. This could be caused by an error processing your message or a receive timeout being exceeded by the remote host, or an underlying network resource issue. Local socket timeout was 'XX:XX:XX.XXXXXX'.

The Socket connection was aborted. This could be caused by an error processing your message or a receive timeout being exceeded by the remote host, or an underlying network resource issue. Local socket timeout was 'XX:XX:XX.XXXXXX'.

Created by Eric Bryant, last modified by Eric Bryant on Jul 08, 2016

Views: 15,103 Votes: 3 Revisions: 15

Overview

The following error message is received when you change a GPO with the SQL Powershell remote execution Policy located at HLM\SOFTWARE\Microsoft\PowerShell\1\ShellIds\Microsoft.SqlServer.Management.PowerShell.sqlps110\ExecutionPolicy from RemoteSigned to Unrestricted value.

 

The Socket connection was aborted. This could be caused by an error processing your message or a receive timeout being exceeded by the remote host, or an underlying network resource issue. Local socket timeout was 'XX:XX:XX.XXXXXX'.

 

Environment

  • All NPM versions

Cause 

This could be a problem with .NET. The TCP port Sharing service is not started before all Orion services. 

This could also be a problem where the following Microsoft Updates KB3102429 was installed.

Resolution

  1. Restart NET TCP port sharing service. Refer to the Microsoft Technet website on how to restart a Windows service http://technet.microsoft.com/en-us/l.../cc772408.aspx.
  2. Restart the Orion Services using the Orion Service Manager.
  3. If the following Microsoft Update KB3102429  is installed, uninstall and restart the Orion server.