2018 is the seventh year for THWACKcamp™, and once again we’ll be live October 17 – 18 with packed session tracks covering everything from network monitoring and management, to change control, application management, storage, cloud and DevOps, security, automation, virtualization, mapping, logging, and more.

Register for online sessions.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Node status is unknown after you change the polling method from External to ICMP

Node status is unknown after you change the polling method from External to ICMP

Created by Su-Lyn Rosenberry-ret, last modified by Su-Lyn Rosenberry-ret on Jul 06, 2016

Views: 1,033 Votes: 0 Revisions: 3

Overview

When you change the node polling method from External to ICMP, the node is not polled and the node status is unknown.

Environment

  • NPM 11.5.2
  • Orion Platform  2015.1.2

Cause 

The ICMP status poller is not created.

Resolution

You must delete and add the node with the ICMP polling method selected.