Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Hardware polling failed: Error 31040 - Timeout

Hardware polling failed: Error 31040 - Timeout

Updated March 22, 2017

Overview

Hardware Health overview resource shows undefined hardware health. The Nodes Details page of nodes that have undefined hardware health, the Hardware details show “Orion hardware polling failed error 31040”. SNMP Tests are successful to these nodes. 

 

Environment

All NPM versions

 

Cause 

Error 31040 is a SNMP timeout from the device.

 

Resolution

Only way to fix it is by increasing the SNMP timeout value or decreasing the latency.

1. From the Orion web console, go to Settings > Polling Settings.

2. From the Polling Settings page, Under Network, look for SNMP TIMEOUT.
3. Change the value of SNMP TIMEOUT to 5000 ms.
4. Click Submit to save the changes.

 

 

 