2018 is the seventh year for THWACKcamp™, and once again we’ll be live October 17 – 18 with packed session tracks covering everything from network monitoring and management, to change control, application management, storage, cloud and DevOps, security, automation, virtualization, mapping, logging, and more.

Register for online sessions.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Errors while using Cisco WLC devices

Errors while using Cisco WLC devices

Table of contents
Created by Interspire Import, last modified by MindTouch on Jun 23, 2016

Views: 1,181 Votes: 0 Revisions: 13

Issue:

The Configuration Wizard fails with the error:

Migration of Orion Jobs to database fail.

Cause: 

Empty registry entries may break the migration.

Resolution:

  1. Click Start > Run > Key-in RegEdit to open the registry editor.
  2. Go to the registry path: HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\SolarWinds.net\Orion Report Scheduler\Settings.
  3. Delete the empty strings from the registry:

     LastSMTPPort
    LastSMTPServerName
  4. Run the Configuration Wizard - Running Configuration Wizard.  

 