2018 is the seventh year for THWACKcamp™, and once again we’ll be live October 17 – 18 with packed session tracks covering everything from network monitoring and management, to change control, application management, storage, cloud and DevOps, security, automation, virtualization, mapping, logging, and more.

Register for online sessions.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Error: SolarWinds.Collector.PollingController.PollingController - Resolve polling plan failed!! We will try to resolve it in next round

Error: SolarWinds.Collector.PollingController.PollingController - Resolve polling plan failed!! We will try to resolve it in next round

Created by Interspire Import, last modified by Jeremy Holmes on Jan 03, 2017

Views: 2,009 Votes: 2 Revisions: 18

Overview

This article describes the issue when NPM monitoring stops and displays incorrect node status with the error: 

SolarWinds.Collector.PollingController.PollingController - Resolve polling plan failed!! We will try to resolve it in next round.

Environment

NPM version 11.0.1

Cause

This issue occurs when the Collector or Job Engines are not functioning properly.

Resolution

  1. Stop the Orion Services - Starting / Stopping Orion Services
  2. Download the NPM v11.0.1 HotFix4 from the Customer Portal
  3. Install the hotfix by double-clicking the executable file.
    Note: After downloading (prior to extracting), right-click on the ZIP file, select properties, and check if file is blocked and unblock if it is.
  4. Start the Orion Services - Starting / Stopping Orion Services
  5. Verify the status of the nodes by clicking the nodes displayed on the NPM Summary screen