Submit a ticketCall us

WebinarFREE IT Monitoring Webcast

Don’t miss out on our webcast, Essential IT Monitoring with SolarWinds ipMonitor, where we will show you how to keep an eye on your IT environment from one centralized, affordable, and lightweight monitoring tool: SolarWinds® ipMonitor®.

Register now.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Error: Object reference not set to instance of an object

Error: Object reference not set to instance of an object

Created by Robert Stidman, last modified by MindTouch on Jun 23, 2016

Views: 4,174 Votes: 1 Revisions: 6

Overview

The following error appears in the Orion Web Console, but is not seen in the Web log.

Object reference not set to instance of an object

Environment

All Orion version with Database Performance Analyzer compatibility

Cause 

Database Performance Analyzer integration requires DPA to be installed.

Resolution

 

  • Uninstall Database Performance Analyzer Integration in the Control Panel and then let the Configuration Wizard run with default configuration; or, install DPA and keep the integration.
     
Last modified

Tags

Classifications

Public