Submit a ticketCall us

AnnouncementsChange Is Inevitable

Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > Network Performance Monitor (NPM) > NPM - Knowledgebase Articles > Error: Job Execution Error: - 2146232060 - Invalid object name LimitationTypeMetadata

Error: Job Execution Error: - 2146232060 - Invalid object name LimitationTypeMetadata

Updated March 10, 2017

Overview

This article goes over why the following error is generated and what steps to conduct to resolve it.

Error: Job Execution Error: - 2146232060 - Invalid object name LimitationTypeMetadata

Environment

All Orion products

Cause 

The Orion Core Services was not properly upgraded or configured in the Configuration Wizard and the LimitationTypesMetaData table is missing.

Resolution

  1. Open Control Panel on the Orion application server > right click Orion Core Services and select Repair.
  2. Run the Configuration Wizard.
  3. Open Orion Database Manager > click Add Default Server.
  4. Expand the Orion Database and search to confirm that the LimitationTypesMetaData table exists.

 

Last modified

Tags

Classifications

Public