Submit a ticketCall us

Get a crash course on Network Monitoring delivered right to your inbox
This free 7-day email course provides a primer to the philosophy, theory, and fundamental concepts involved in IT monitoring. Lessons will explain not only how to perform various monitoring tasks, but why and when you should use them. Sign up now.

Home > Success Center > Network Performance Monitor (NPM) > HP 5500-48G-4SFP HI Switch does not poll for VLAN statistics

HP 5500-48G-4SFP HI Switch does not poll for VLAN statistics

Table of contents

Updated August 31, 2016

Overview

This article discusses why HP 5500-48G-4SFP HI Switch is not polling for VLAN statistics.

Environment

  • NPM 12
  • HP 5500-48G-4SFP HI Switch

Detail

Orion NPM supports VLAN polling of HP devices using Generic OIDs. See below.

  • dot1qVlanFdbId 1.3.6.1.2.1.17.7.1.4.2.1.3 
  • dot1qVlanStaticName 1.3.6.1.2.1.17.7.1.4.3.1.1 
  • dot1qVlanCurrentEgressPorts 1.3.6.1.2.1.17.7.1.4.2.1.4 

But for HP 5500-48G-4SFP HI Switch, NPM cannot poll for VLAN statistics because the said device only supports the OID "dot1qVlanStaticName 1.3.6.1.2.1.17.7.1.4.3.1.1".

 

Reference: " MIB Companion > A5500HI MIB Companion.pdf " included in the below download for all supported OIDs..
https://h10145.www1.hpe.com/downloads/SoftwareReleases.aspx?ProductNumber=JG312A&lang=&cc=&prodSeriesId=

 

 

 

Last modified
18:48, 30 Aug 2016

Tags

Classifications

Public