The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > HP 5500-48G-4SFP HI Switch does not poll for VLAN statistics

HP 5500-48G-4SFP HI Switch does not poll for VLAN statistics

Table of contents

Updated August 31, 2016

Overview

This article discusses why HP 5500-48G-4SFP HI Switch is not polling for VLAN statistics.

Environment

  • NPM 12
  • HP 5500-48G-4SFP HI Switch

Detail

Orion NPM supports VLAN polling of HP devices using Generic OIDs. See below.

  • dot1qVlanFdbId 1.3.6.1.2.1.17.7.1.4.2.1.3 
  • dot1qVlanStaticName 1.3.6.1.2.1.17.7.1.4.3.1.1 
  • dot1qVlanCurrentEgressPorts 1.3.6.1.2.1.17.7.1.4.2.1.4 

But for HP 5500-48G-4SFP HI Switch, NPM cannot poll for VLAN statistics because the said device only supports the OID "dot1qVlanStaticName 1.3.6.1.2.1.17.7.1.4.3.1.1".

 

Reference: " MIB Companion > A5500HI MIB Companion.pdf " included in the below download for all supported OIDs..
https://h10145.www1.hpe.com/downloads/SoftwareReleases.aspx?ProductNumber=JG312A&lang=&cc=&prodSeriesId=

 

 

 