Overview

The F5 Sync status reflects are Unknown in F5 devices with firmware using NPM versions 11.2 and earlier. 

Environment

NPM versions 10.4 and later

Cause

The issue is caused by NPM polling OIDs in F5-BIGIP-SYSTEM-MIB to determine F5 Sync Status.

Resolution

Upgrade the firmware of your F5 devices to at least NPM version 11.2.

 

 

Polled OID Notes
1.3.6.1.4.1.3375.2.1.14.1.1 (sysCmSyncStatusId) F5 devices on firmware versions older than 11.2 do not report values for this OID.
1.3.6.1.4.1.3375.2.1.1.1.1.6 (sysAttrConfigsyncState) F5 Sync status is determined for F5 devices with firmware version older than 11.2 by transforming the value polled in accordance with the following table:
sysAttrConfigsyncState sysCmSyncStatusId
-1 - uninitialized or disabled config state unknown(0)
0 - Synchronized inSync(3)
1 - Local config modified, recommend configsync to peer needManualSync(2)
2 - Peer config modified, recommend configsync from peer needManualSync(2)