Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Network Performance Monitor (NPM) > Error: Object reference not set to instance of an object

Error: Object reference not set to instance of an object

Created by Robert Stidman, last modified by MindTouch on Jun 23, 2016

Views: 421 Votes: 1 Revisions: 6

Overview

The following error appears in the Orion Web Console, but is not seen in the Web log.

Object reference not set to instance of an object

Environment

All Orion version with Database Performance Analyzer compatibility

Cause 

Database Performance Analyzer integration requires DPA to be installed.

Resolution

 

  • Uninstall Database Performance Analyzer Integration in the Control Panel and then let the Configuration Wizard run with default configuration; or, install DPA and keep the integration.
     