Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Network Performance Monitor (NPM) > Error: Object reference not set to an instance of an object

Error: Object reference not set to an instance of an object

Updated September 8, 2016

Overview

The following error occurs when editing a page, view or web resource. It can also display when clicking on any node object:

Object reference not set to an instance of an object

Environment

Orion Core products

 

Cause 

The error is caused by a corrupted or incorrectly formatted  resource folder in the C:\Inetpub\SolarWinds\Orion directory.

Resolution

Rebuilding the website on the Orion application server will resolve the issue. For issues where this error is displayed when clicking on a node object, a re-set of IIS may be sufficient to resolve this issue. As is this a more straight forward fix than rebuilding the website, we recommend this is attempted first to see if it resolves.

 

 

 

 