Patch Manager is an intuitive patch management software which extends the capabilities of WSUS and SCCM to not only patch Windows® servers and workstations, and Microsoft® applications, but also other 3rd-party applications which are commonly exploited by hackers. Learn more about our patch management solution.

 

Home > Success Center > Network Performance Monitor (NPM) > Error 500 on the NPM Web Console if WSUS server is installed on the same server

Error 500 on the NPM Web Console if WSUS server is installed on the same server

Created by Justin Wyllys, last modified by Rodim Suarez on Jun 29, 2017

Views: 57 Votes: 1 Revisions: 17

Overview

Patch Manager installs components by default, including WSUS. SolarWinds recommends not to install WSUS where the NPM server is located. The Error 500 message is displayed on the NPM Web Console if the WSUS server is installed on the same NPM server.

Environment

Orion NPM and WSUS installed on the same server

Cause

NPM and WSUS share a compression DLL file but have different compression methods. This causes the NPM Web Console to crash.

Resolution

Uninstall WSUS and Patch Manager if they are in the same location with the NPM server or perform the following steps as a workaround:

  1. Enter the following command to fix Orion:

    %windir%\system32\inetsrv\appcmd.exe set config -section:system.webServer/httpCompression /-[name='xpress']

  2. Reset IIS using the following command: 

    iisreset 

If the issue is not resolved, reinstall IIS with the appropriate port bindings.

 

Note: When installing Patch Manager, WSUS should be on the remote server and the IIS bindings are set up separately from the Orion Web Console bindings. Use the Advanced settings during Patch Manager installation to allow you to set up separate IIS bindings and connect to the remote WSUS server.

 