Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Network Performance Monitor (NPM) > Email alert showing exponential value instead of actual bandwidth utilization in mbps units

Email alert showing exponential value instead of actual bandwidth utilization in mbps units

Updated December 13, 2016

Overview

After upgrading using the 11.0 > 11.5.3 > 12.0 > 12.0.1 path, alerts were not 

Alerts were not properly migrated after upgrading using the 11.0 > 11.5.3 > 12.0 > 12.0.1 path. This resulted to the actual value of bandwidth utilization not being interpreted correctly within email alert.

For example, it is showing as 8.706991E+07 instead of the actual mpbs values (984622mbps) in the email alert being received.

Environment

NPM 12.0.1

Cause 

The alert was not migrated properly from the previous to the later Orion version.

Resolution

  1. Edit the alert triggered action.
  2. Add the variable to display the actual bandwidth utilization correctly ${N=SwisEntity;M=Outbps;F=Bandwidth}bps.

 

 

 

Last modified
16:51, 12 Dec 2016

Tags

Classifications

Public