Overview

The Edit Properties button is disabled or grayed when you select one or more nodes in the Manage Nodes page. As a result, you are unable to edit nodes in bulk. 

Environment

Orion Platform 2016.2

Cause 

This issue occurs when the ObjectSubType value in the NodesData table is set to ['snmp', 'icmp', 'wmi'] instead of ['SNMP', 'ICMP', 'WMI'] (in upper case).

Resolution

Note: Create a backup of your Orion database before performing the following steps.

  1. Go to Start > SolarWinds Orion > Advanced Features > Database Manager.

  2. Click Add Server (Add Default Server).

  3. Right-click on your SolarWindsOrion database and then select New Query.

  4. Execute the following query:

update [NodesData] set ObjectSubType='SNMP' where ObjectSubType='snmp'
update [NodesData] set ObjectSubType='WMI' where ObjectSubType='wmi'
update [NodesData] set ObjectSubType='ICMP' where ObjectSubType='icmp'

 