Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Network Performance Monitor (NPM) > ERROR: INFO  SolarWinds.Orion.Common.SWEventLogging - IPv6 TCP Listening Disabled

ERROR: INFO  SolarWinds.Orion.Common.SWEventLogging - IPv6 TCP Listening Disabled

Created by Jeremy Holmes, last modified by MindTouch on Jun 23, 2016

Views: 1,503 Votes: 0 Revisions: 3

Overview

The Syslog Service is not starting on a Solarwinds server.

 

2016-03-11 14:42:26,047 [StartupThread] INFO  SolarWinds.Orion.Common.SWEventLogging - IPv6 TCP Listening Disabled
2016-03-11 14:42:26,047 [UDPListenerThreadIpv6] INFO  SolarWinds.Orion.Common.SWEventLogging - Syslog Collector Started on :: IPv6 UDP Port 514
2016-03-11 14:42:26,063 [UDPListenerThread] ERROR SolarWinds.Orion.Common.SWEventLogging - Syslog Service Unhandled Exception Only one usage of each socket address (protocol/network address/port) is normally permitted
   at System.Net.Sockets.Socket.DoBind(EndPoint endPointSnapshot, SocketAddress socketAddress)
   at System.Net.Sockets.Socket.Bind(EndPoint localEP)
   at System.Net.Sockets.UdpClient..ctor(IPEndPoint localEP)
   at SolarWinds.Syslog.UdpPacketListener`1.ListenForSyslogPackets(Boolean isIpv6, IPEndPoint localEndPoint, IRunState runState)
   at SyslogService.SyslogService.ListenForUDPPacket(Object ipv6)
   at System.Threading.ThreadHelper.ThreadStart_Context(Object state)
   at System.Threading.ExecutionContext.RunInternal(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
   at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean preserveSyncCtx)
   at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)
   at System.Threading.ThreadHelper.ThreadStart(Object obj)

Environment

Orion 2013 and later

Cause 

This is due to a port conflict with another Syslog Service such as Kiwi.

 

Resolution

  • Disable the other Service or Application, per steps of that product, that is using the port (UDP 514).
  • If you would rather keep using that Service or Application and not use Orion's Syslog service, then disable the automatic start of the service using Windows Service Manager. 