Having a unified ticketing and asset management system for all the departments in your company can provide end-users with a seamless experience and make things easier for your IT team. Yet, with different business tasks and objectives, many departments don’t fully understand the capabilities of Web Help Desk and how the software can be customized for effective use in their departments.
Register Now.

Home > Success Center > Network Performance Monitor (NPM) > Custom List Reports: Object reference not set to an instance of an object

Custom List Reports: Object reference not set to an instance of an object

Created by Jeremy Holmes, last modified by MindTouch on Jun 23, 2016

Views: 38 Votes: 0 Revisions: 3

Overview

The following error appears when attempting to edit/access the Custom List of Reports resources:

Object reference not set to an instance of an object.

Environment

NPM 11.5.3

Cause 

The resource could not complete its query.

Resolution

  1. Go to Start > All Programs > Solarwinds Orion > Documentation and Support > Log Adjuster and set the website to Debug.
  2. Reproduce the issue on the webpage by trying to edit the resource.
  3. Review the OrionWeb.log (C:\programdata\solarwinds\logs\Orion) and see which report it was querying before the error occurred.
  4. Review that report and make sure that there are no duplicate titles and that the report is a valid/working.
  5. Fix any issues you find and retest the page load.

 