Submit a ticketCall us

Solarwinds & Cisco Live! Barcelona
Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Network Performance Monitor (NPM) > Custom List Reports: Object reference not set to an instance of an object

Custom List Reports: Object reference not set to an instance of an object

Created by Jeremy Holmes, last modified by MindTouch on Jun 23, 2016

Views: 1,317 Votes: 0 Revisions: 3

Overview

The following error appears when attempting to edit/access the Custom List of Reports resources:

Object reference not set to an instance of an object.

Environment

NPM 11.5.3

Cause 

The resource could not complete its query.

Resolution

  1. Go to Start > All Programs > Solarwinds Orion > Documentation and Support > Log Adjuster and set the website to Debug.
  2. Reproduce the issue on the webpage by trying to edit the resource.
  3. Review the OrionWeb.log (C:\programdata\solarwinds\logs\Orion) and see which report it was querying before the error occurred.
  4. Review that report and make sure that there are no duplicate titles and that the report is a valid/working.
  5. Fix any issues you find and retest the page load.

 

Last modified

Tags

Classifications

Public