Submit a ticketCall us

Don’t fall victim to a ransomware attack
Backups are helpful, but sometimes that’s not enough to protect your business against ransomware. At our live webcast we will discuss how to protect against ransomware attacks with SolarWinds® Patch Manager and how to leverage log data to detect ransomware. Register now for our live webcast.

Home > Success Center > Network Performance Monitor (NPM) > Create an advanced SQL report to check nodes that fail SNMP\WMI polling

Create an advanced SQL report to check nodes that fail SNMP\WMI polling

Table of contents
No headers

Updated March 11th, 2016

 

  1. Go to Report Writer (Start > All Programs > SolarWinds Orion > Alerting, Reporting, and Mapping > Report Writer)
  2. Select File Menu > New Report
  3. Choose "Advanced SQL"  as the report type
  4. The following advanced SQL report checks the last 5 polls where snmp\wmi communication has been destroyed
    • SELECT Nodes.NodeID AS NetObject, Nodes.Caption AS NameFROM NodesWhere LastSystemUpTimePollUtc <
    • DATEADD( second, -5*PollInterval, GETUTCDATE()) AND status =1 AND ObjectSubType IN ('SNMP', 'WMI')
  5.  The Preview option helps to see the results. Also the report can be saved for latter use.
Last modified
15:29, 7 Apr 2017

Tags

Classifications

Public