Submit a ticketCall us

Have You Auto Renewed? If not, you're missing out.
The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Network Performance Monitor (NPM) > Connection errors when installing NPM additional web server

Connection errors when installing NPM additional web server

Updated May 17, 2017

Overview

The following error is displayed when installing NPM 12.1 WebOnly or an additional web server:

An Error Has Occurred

Error Description:

Can't receive data from SolarWinds Information Service

This request operation sent to

net.tcp://happ30:17777/SolarWinds/InformationService/v3/Orion/ssl did not receive a reply within the configure timeout (00:00:29.6734056). The time allotted to this operation may have been a portion of a longer timeout. This may be because the service is still processing the operation or because the service was unable to send a reply message. Please consider increasing the operation timeout (by casting the channel/proxy to IContextChannel and setting the OperationTimeout properly) and ensure that the service is able to connect to the client.

 

A message in the OrionInstaller.log file also indicates an error with the OIP server connection:

2017-05-12 14:21:20,250 [1] INFO  OrionInstallerLib.OrionImprovement.OipClient - Tracking event: Orion Standalone Installer - InstallActionCommand - Action will wait for process to complete - True - 0
2017-05-12 14:21:20,250 [1] DEBUG OrionInstallerLib.InstallActionCommand - Parsed Filename .\SubInstallers\SolarWinds.Orion.CompatibilityChecker.exe with parsed command line of "-module NPM -version 12.1.5300".
2017-05-12 14:21:39,329 [4] DEBUG OrionInstallerLib.OrionImprovement.OipClient - Error checking OIP server connection.
System.Net.WebException: Unable to connect to the remote server ---> System.Net.Sockets.SocketException: A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond 74.115.12.127:443
   at System.Net.Sockets.Socket.DoConnect(EndPoint endPointSnapshot, SocketAddress socketAddress)
   at System.Net.ServicePoint.ConnectSocketInternal(Boolean connectFailure, Socket s4, Socket s6, Socket& socket, IPAddress& address, ConnectSocketState state, IAsyncResult asyncResult, Exception& exception)
   --- End of inner exception stack trace ---
   at System.Net.WebClient.DownloadDataInternal(Uri address, WebRequest& request)
   at System.Net.WebClient.DownloadString(Uri address)
   at System.Net.WebClient.DownloadString(String address)
   at OrionInstallerLib.OrionImprovement.WebApiClient.Get(String url, HttpRequestCacheLevel cache)
   at OrionInstallerLib.OrionImprovement.OipClient.CheckServerConnection(OipClient client)
2017-05-12 14:21:39,345 [4] INFO  OrionInstallerLib.OrionImprovement.OipClient - Not connected to OIP server, OIP data will NOT be transmitted.

Environment

NPM 12.1

Cause 

The error is due to the proxy settings in Internet Explorer.

Resolution

  1. Open Internet Explorer.
  2. Click the gear icon, and then click Internet Options.
  3. Under the Connections tab, click LAN Settings.
  4. Set the proper configuration, and then save the changes.

 

Last modified

Tags

Classifications

Public