Created by Malik Haider, last modified by Kevin.Swinson on Nov 09, 2017

Views: 766 Votes: 0 Revisions: 14

Updated April 24th, 2016



Configuration Wizard taking very long time to finish 

Configuration wizard hangs on some stage and not finishing 

  • Upgrading running NPM 11.5 installer and Configuration Wizard will halt 
  • Configuration Wizard halted / Building web request


Checking the Configuration Wizard Logs found the below Errors. 


Line 2: 2014-06-05 12:11:23,867 [7] VERBOSE Main - SNMP_SocketRecyclingInterval is [30] 
Line 3: 2014-06-05 12:11:23,883 [7] VERBOSE Main - SNMP_SocketKeepAliveInterval is [10] 
Line 12997: 2014-06-05 12:12:23,896 [14] VERBOSE Main - SNMP_SocketRecyclingInterval is [30] 
Line 13876: 2014-06-05 12:22:24,014 [15] VERBOSE Main - SNMP_SocketKeepAliveInterval is [10] 



  • NPM 10.7 and later versions 


Due to the Active entry in the DB table with previously unfinished Configuration Wizard could cause such issue. 



Delete the active entry from the DB as below 


  1. Open Orion Database Manager 
  2. Orion Database Manager > Select Orion Database > Right Click > New Query 
  3. Paste the query > SELECT * FROM Settings WHERE SettingID LIKE 'CW-ActiveInstance-%'
  4. Execute Query > and delete all the found rows by > Enable table editing > Right Click on the rows and Delete the selected rows deleteq.PNG
  5. Now re run the Configuration Wizard again.



Please Note : This particular behavior of application  is been resolved in the next version of release therefor we strongly recommend to upgrade Orion to the latest versions available. 