Updated March 7th, 2016

Overview

This article provides brief information and steps to resolve the following Orion Configuration Wizard error:

<Interface.strings.dll not accessible> 

Environment

All NPM versions

 

Cause 

Multiple users logged on to the Orion Server. One of the other users was using the Report Writer application. The configuration wizard could not update the dll as it was open in the other session.

Resolution

  1. Right-click on the Windows Task bar and launch the task manager.
  2. Go to the User tab.
  3. Right-click any users other than the account you are working with and select Sign Off.
  4. Re-run the Configuration Wizard.

 

 

 