Overview

The Current Hardware Health resource is showing correct temperature readings but the status is "major" instead of "normal."

Environment

  • NPM 11.5.2
  • Cisco Catalyst 3560 Series 

Cause 

Orion is polling for a global MIB instead of a specific Cisco MIB.

Resolution

  1. Open the Orion Web Console.
  2. Select the affected node in the Manage nodes resource.
  3. Click Edit node in the Management resource.
  4. Under Hardware Health Polling for Preferred Cisco MIB, select CISCO-ENTITY-SENSOR-MIB instead of the Global One.
  5. Click Submit.
    Note: This will only be visible if the Hardware Health Sensors are selected in List resources